Common table
This table is present and identical for all devices.
Address (hex) | Address (dec) | Size | description | Unit | Data Type |
---|---|---|---|---|---|
0x00 | 0 | 1 | µWiotys version |
| U16 |
0x01 | 1 | 4 | DevEUI |
| U64 |
0x05 | 5 | 1 | Device Wi6labs reference ID |
| U16 |
0x06 | 6 | 2 | Last uplink timestamp (in UNIX format) |
| U32 |
0x08 | 8 | 2 | Last uplink frame counter |
| U32 |
0x0A | 10 | 4 | RFU |
| U64 |
0x0E | 14 | 1 | SF |
| U16 |
0x0F | 15 | 1 | RSSI |
| S16 |
0x10 | 16 | 1 | SNR |
| S16 |
0x11 | 17 | 1 | Device Battery | % | U16 |
0x12 | 18 | 1 | Device Battery | mv | U16 |
0x13 | 19 | 1 | Device version |
| U16 |
0x14 | 20 | 1 | Device configuration |
| U16 |
0x15 | 21 | 125 | Payload |
| Byte Field |