Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Panel
panelIconId1f6e0
panelIcon:tools:
panelIconText🛠️
bgColor#F4F5F7

Please be patient with those steps, start up the gateway and actions with FTP can take a long time

...

Note

Warning the response time of µWiotys' FTP can be a little bit long, especially on fixed IP.
If necessary, you should extend your FTP Client timeout to 60 seconds, see Application Example

Don’t forget to refresh in order to see your current files

Contact your seller for user/password

End device configuration

LoRaWAN device provisioning on µWiotys can be done by FTP transfer.
First, create the configuration file with proper parameters and format then connect to µWiotys with FTP and copy the configuration file into the proper directory.

...

  1. Copy the devices configuration file into the directory: /uwiotys/update_config/

  2. Create an empty file named "reboot" in directory "/update/". You can reboot with this method or with the reboot web interface button

Note

An electric reboot can corrupt the update process !

Info

Few milliseconds after, a "reboot_processed_ok" file will be created. You can log out of your GW and move on to the next step.

  1. After few minutes

    1. If the update failed, you will find information into the file: devices_updates_$DATE_ERROR.log

    2. If the update success, the file the devices configuration file is deleted and you will find the file: devices_updates_$DATE_SUCCESS.log

  2. The devices current configuration of µWiotys is available in the directory: /uwiotys/current_config/

...

  • "No license found, µWiotys will not start. Please configure a valid license for your µWiotys gateway XXXXXXXX" when NO license is present.

  • "The license is VALID. µWiotys will start." when the product HAS a license.

How to know the license's type and state

...