LoRaWAN Compatible Devices
Here is the list of LoRaWAN devices available with µWiotys.
If you are looking for a specific device that is not listed, please contact Wi6labs support.
The Watteco (NKE) devices with standard frames are supported and some of Watteco (NKE) device is supported with only the last value of default BATCH mode!
Click on the manufacturer reference to get the Modbus table.
Manufacturer | Manufacturer reference | Name | Modbus table | µWiotys minimum version |
---|---|---|---|---|
ADEUNIS | Adeunis Field Test Device (FTD) | Common | 1.1.0 | |
ADEUNIS | ARF8123AAH | Adeunis Field Test Device (FTD) | Common | 1.1.0 |
ADEUNIS | Dry Contact state report (also include sensors ARF8170BA with integrated accessories water leak, double level, door contact...) (dry contact 1) | Industrial | 1.0.0-rc1 | |
ADEUNIS | ARF8180BCA | Record temperatures: measure, track changes and alert if thresholds are exceeded (temp 4) | Temperature Humidity | 1.3.0 |
ADEUNIS | Measure temperatures simultaneously at two locations (temp 4) | Temperature Humidity | 1.3.0 | |
ADEUNIS | ARF8190BA | On battery or external power supply, connect your 0-10 V or 4-20 mA sensors (Analog) | Industrial | 1.3.0 |
ADEUNIS | ARF8230AA | Impulse interface (Pulse v4 - 0x5A - 0x5B - 0x46) | Energy | 1.3.0 |
ADEUNIS | Impulse interface (Pulse v4 - 0x5A - 0x5B - 0x46) | Energy | 1.3.0 | |
ADEUNIS | Optimize the comfort of occupants and the energy consumption of a building (comfort 2) | Temperature Humidity | 1.3.0 | |
ADEUNIS | Modbus Class C | Modbus | 3.4.4 | |
AE SENSOR | AELoadCell | Weight measure up to 100Kg | Temperature Humidity Industrial Environment | 3.2.0 |
DIEHL | G3 module for water consumption | Energy | 1.3.3 | |
ECOADAPT | PowerElec meter with 6 connectors to measure Active/Reactive power Float type representation : From V3.5.0 -> ABCD Before V3.5.0 -> DCBA | Energy | 3.4.3 | |
TCT | Current clamp that measure Current, Temperature (+ Battery voltage of sensor) Float type representation : From V3.5.0 -> ABCD Before V3.5.0 -> DCBA | Temperature, Energy | 3.4.3 | |
EASTRON | PowerElec no-intrusive meter that permits to measure Energy / Current / Voltage | Energy | 3.5.0 | |
ELSYS | Smart Building Sensor for indoor environment monitoring | Temperature Humidity, Environment, Industrial | 2.4.0 | |
ELSYS | ERS_lite | Smart Building Sensor for indoor environment monitoring | Temperature Humidity | 2.4.0 |
ELSYS | Smart Building Sensor for indoor environment monitoring | Temperature Humidity, Environment, Industrial | 2.4.0 | |
ELSYS | ERS_lite_CO2 | Smart Building Sensor for indoor environment monitoring | Temperature Humidity, Environment | 2.4.0 |
ELSYS | ERS_VOC | Smart Building Sensor for indoor environment monitoring | Temperature Humidity, Environment, Industrial | 2.4.0 |
ELVACO | CMa11L | Temperature Humidity | Temperature Humidity | 1.3.0 |
ELVACO | Itron CF 51/55/ECHO II | Temperature Humidity, Energy | 2.4.0 | |
ELVACO | Diehl Sharky 775 | Energy | 1.3.0 | |
Enless | TX_Pulse |
| Energy | 2.3.0 |
Enless | TX_Pulse_ATEX |
| Energy | 2.3.0 |
Enless | TX_Pulse_LED |
| Energy | 2.3.0 |
Enless | TX_TEMP_CONT1 | Temperature | Energy | 2.3.0 |
Enless | TX_TEMP_CONT2 | Temperature | Energy | 2.3.0 |
Enginko | Actuator ON/OFF | Industrial | 3.4.2 | |
LACROIX_SOFREL | T-INDOOR | LACROIX Sofrel Temperature | Temperature Humidity | 2.2.0 |
LACROIX_SOFREL | T-OUTDOOR | LACROIX Sofrel Temperature | Temperature Humidity | 2.2.0 |
LOGAREX | SafeMeter Float type representation : From V3.5.0 -> ABCD Before V3.5.0 -> DCBA | Energy | 1.3.0 | |
MILESIGHT | Environment Monitoring Sensor | Temperature Humidity | 2.3.0 | |
MILESIGHT | Smart Button | Industrial | 2.3.0 | |
NEXELEC | Measure the level of CO2 and optimize the renewal of indoor air | Environment | 1.3.3 | |
NEXELEC | Smoke detector | Environment + Industrial + Temperature Humidity | 2.3.0 | |
SAMEA | SENSORIIS | Sensoriis | Temperature Humidity + Industrial | 1.1.0 |
SENSAIO | Valve positioning | Temperature Humidity + Environment | 3.3.0 | |
SENSAIO | Pressure | Temperature Humidity + Environment | 3.3.0 | |
SENSAIO | Temperature | Temperature Humidity + Environment | 3.3.0 | |
SOCOMEC | 48290900 | Diris B-10 Lora (B10L) Multifunction power monitoring device | B10 | 1.0.0 |
SOCOMEC | 48290901 | L-TRH Indoor Temperature/Humidity Sensor | Temperature Humidity | 1.2.0 |
SOCOMEC | 48290902 | L-T Remote Temperature Sensor | Temperature Humidity | 1.2.0 |
SOCOMEC | 48290903 | L-PW Pulse Input Sensor (waterproof) | Energy | 1.2.0 |
SOCOMEC | 48290904 | L-DI/DO Digital Input/Output Sensor | Industrial | 1.2.0 |
SOCOMEC | 48290905 | L-AI Analog Input Sensor | Industrial | 1.2.0 |
SOCOMEC | 48290906 | L-Modbus Interface | Modbus | 1.2.0 |
TEKELEK | TEK766 | liquid level monitoring | Temperature Humidity + Environment + Industrial | 2.5.1/3.1.1 |
THERMOKON | Outdoor sensor for relative humidity an temperature | Temperature, Humidity | 2.4.0 | |
THERMOKON | LoRaWAN compact multi sensor | Temperature, Humidity, Environment | 2.4.0 | |
WATTECO | Remote temperature | Temperature Humidity | 1.0.0-rc1 | |
WATTECO | 50-70-049 | Cels’O | Temperature Humidity | 1.0.0-rc1 |
WATTECO | 50-70-096 | Cels’O | Temperature Humidity | 1.0.0-rc1 |
WATTECO | 50-70-097 | Cels’O | Temperature Humidity | 1.0.0-rc1 |
WATTECO | 50-70-085 | TH indoor (support last value of default batch mode) | Temperature Humidity | 1.0.0-rc1 |
WATTECO | 50-70-167 | TH indoor (support last value of default batch mode) | Temperature Humidity | 1.4.0 |
WATTECO | 50-70-007 | THr (support last value of default batch mode) | Temperature Humidity | 1.0.0-rc1 |
WATTECO | 50-70-047 | THr Plus (support last value of default batch mode) | Temperature Humidity | 1.0.0-rc1 |
WATTECO | 50-70-053 | TH indoor (support last value of default batch mode | Temperature Humidity | 1.0.0-rc1 |
WATTECO | TH indoor (support last value of default batch mode | Temperature Humidity | 1.4.0 | |
WATTECO | 50-70-139 | Remote temperature 2 probes | Temperature Humidity | 1.0.0-rc1 |
WATTECO | Remote temperature 2 probes | Temperature Humidity | 1.0.0-rc1 | |
WATTECO | 50-70-017 | PRESS’O analog | Industrial | 1.0.0 |
WATTECO | 50-70-016 | IN'O (class A) state report | Industrial | 1.0.0 |
WATTECO | IN'O (class C) state report | Industrial | 1.0.0 | |
WATTECO | Pulse SENS’O (support last value of default batch mode) | Energy | 1.2.0 | |
WATTECO | Pulse SENS’O (support last value of default batch mode) | Energy | 1.4.0 | |
WATTECO | Pulse SENS’O IP68 (support last value of default batch mode) | Energy | 1.2.0 | |
WATTECO | Pulse Sens'O IP68 ATEX (support last value of default batch mode) | Energy | 1.2.0 | |
WATTECO | Pulse SENS’O AtEX zone1 (support last value of default batch mode) | Energy | 1.2.0 | |
WATTECO | Pulse SENS’O AtEX zone2 (support last value of default batch mode) | Energy | 1.2.0 | |
WATTECO | 50-70-071 | Flash'O devices | Energy | 1.2.0 |
WATTECO | 50-70-080 | Modbus Class A | Modbus | 1.2.0 |
WATTECO | Modbus Class C | Modbus | 1.2.0 | |
WATTECO | 50-70-142 | Remote temperature | Temperature Humidity | 2.1.0 |
WATTECO | 50-70-184 | Remote temperature 2 probes | Temperature Humidity | 2.1.0 |
WATTECO | Vaqa’O | Temperature, Hygrometry, VOC, CO2 | 2.3.0 | |
WATTECO | 50-70-074 | Vaqa’O+ | Temperature, Hygrometry, VOC, CO2 | 2.3.0 |
WATTECO | Pilot Wire | Industrial | 2.3.1 | |
WIRELESS4YOU | IoTHUB | Modbus to Lora adapter for multiple sensors : temperature, conductivity, PH,... | Modbus | 1.3.3 |
YOKOGAWA | Pressure Measurement Module | Temperature Humidity + Environment | 2.1.0 | |
YOKOGAWA | Temperature Measurement | Temperature Humidity | 2.1.0 | |
YOKOGAWA | Vibration Measurement | Temperature Humidity + Environment | 2.2.0 |